Bring out the best in your MRI.

Your scanner. Your sequences. Your clinical goals. We help your team optimize MRI performance and tailor protocols to the demands of radiation oncology and diagnostic radiology.

Discuss a project

NEWS • ACCELERATE 2026
SpinTecx presented MRIQA at the InvestMS Scale-Up Pitch. We are aiming to raise $2M to advance MRIQA development, validation and commercialization. Read the full update →

Board-certified expertiseOn-site • Remote • Hybrid

Your clinical purpose comes first.

The right MRI protocol starts with what your team needs to see and measure. We work with you to assess image quality, understand spatial accuracy and refine the sequences you use. Our goal is practical: help you get more from the MRI system you already have, with clear findings and a plan you can use.

Illustrative phantom-only report. Preliminary findings; a separate anonymized example from the UCLA study below.

Built around your practice.

Our work is rooted in the precision demands of radiation oncology and extends to diagnostic radiology. We tailor our support to your scanner, coils, sequences and clinical applications, working alongside your existing physics and vendor teams.

MRI for radiotherapy

  • MRI simulation and the MRI components of MR-linac commissioning
  • Geometric-distortion assessment and SRS sequence optimization
  • Phantom baselines and continuing MRI QA review

MRI for radiology

  • MRI performance testing and protocol assessment
  • Customized pulse-sequence and image-quality optimization
  • QA workflows and continuing physicist support

MRI physics consulting is available separately from software programs in development.

Start with what you want to improve.

Bring us a clinical imaging question, a new MRI application or a protocol you want to refine. Together, we define a focused consulting project with clear deliverables and an agreed fee.

Know your MRI’s starting point.

For a new MRI service, system upgrade or new clinical application. Receive an agreed testing plan, documented performance baselines, a QA workflow and a review meeting. MR-linac work focuses on the MRI components.

Shape sequences around your clinical needs.

Evaluate selected sequences for one clinical question. Receive phantom measurements, a comparison of image quality and spatial fidelity, practical protocol recommendations and a repeat-testing plan.

Keep performance in focus.

Build continuing support around your existing vendor and physics coverage. Scope can include QA trend reports, protocol-change reviews, staff guidance and reassessment after upgrades.

How we work together

We listen to your goals, measure what matters for your application and work with your team to refine and verify changes. You receive documented findings, practical recommendations and support that fits your workflow—on-site, remotely or through a hybrid approach.

Your clinical team retains protocol approval and patient-care decisions.

Tools in service of your goals.

MRIQA RadOnc Phantom QA • In validation

Our MRIQA software, GHead and ACR phantoms support a shared purpose: understanding how your MRI performs for the work you do. We use measurements and physicist review to guide site-specific assessment and practical recommendations.

GHead

Characterize geometric distortion using a controlled head-shaped lattice and air-cavity interfaces.

ACR

Assess scanner image quality and evaluate your clinical sequences on a standard phantom.

MRIQA RadOnc

Bring measurements, maps and comparisons into reports with practical recommendations for qualified physicist review.

Scanning instructions, analysis and physicist review are tailored to the scanner, coils, sequences and setup, with scope and delivery agreed with your team.

GHead phantom

Preliminary UCLA phantom evaluation

Siemens MAGNETOM Sola 1.5 T • 3D MPRAGE test protocol • 8 October 2026

GHead displacement, 95th percentile

Vendor 3D correction OFF

1.24 mm

Vendor 3D correction ON

0.50 mm

Same-session comparison across 9,789 sampled lattice points, measured against phantom design geometry. Our software measures the effect of the scanner's correction setting.

Preliminary research analysis: one scanner and session, with final physicist review pending. Not clinical acceptance or a validated product-performance claim.

Separate anonymized example; preliminary results.

Research & Future Development

MRIQA RadOnc Clinical QA

Research Only

A research application evaluating volunteer image quality and field-map-derived B0 displacement estimates to investigate sequence tradeoffs alongside the phantom baseline. Research use only. Not for diagnosis or treatment-planning decisions.

MRIQA Radiology

In Development

Physics-guided quality assessment and protocol optimization for diagnostic MRI, tailored to the scanner, coils and imaging task.

MRI physics consulting is available separately.

See our preliminary validation findings, submitted abstracts and recent presentations.

What would you like your MRI to do better?

Tell us about your scanner, your clinical application and the challenge your team wants to solve. We’ll help you define a practical starting point. Please do not include patient information or confidential data.

Ali Fatemi, PhD, MCCPM, DABMP (MR in RT)

Founder & Chief Clinical Medical Physicist

Clinical medical physicist, entrepreneur and educator focused on MRI quality, geometric accuracy and radiotherapy imaging.